If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
HCE Series Miniature amplified pressure sensors FEATURES * 10 mbar to 5 bar, absolute, gage or differential pressure * Barometric pressure ranges * Digital SPI bus and analog output * Precision ASIC signal conditioning * Calibrated and temperature compensated * Matched pressure port volumes * Miniature SMD housings * RoHS compliant * Sensortechnics PRO services SPECIFICATIONS Maximum ratings Supply voltage VS HCE...3 HCE...5 Output current Sink Source ELECTRICAL CONNECTION 2.7 ... 3.3 VDC 4.5 V ... 5.5 VDC max. 6.50 VDC 1 mA 1 mA 1 4 5 6 8 2 +Vs MISO CLK SS MOSI GND Vout 3 Lead specifications Average preheating temperature gradient 2.5 K/s Soak time ca. 3 min Time above 217C 50 s Time above 230C 40 s Time above 250C 15 s Peak temperature 260C Cooling temperature gradient -3.5 K/s Temperature ranges6 Compensated Operating Storage Humidity limits (non-condensing) 0 ... 85C -25 ... 85C -40 ... 125C 0 ... 95 %RH Note: Connections for digital SPI bus (pins 4 to 6) are only available for SMD package styles (E, H and Q housings). E / 11652 / A 1/11 www.sensortechnics.com HCE Series Miniature amplified pressure sensors PRESSURE SENSOR CHARACTERISTICS (TA = 25 C) Part no. HCEM010...B... HCEM020...B... HCEM050...B... HCEM100...B... HCEM200...B... HCEM500...B... HCEB001...B... HCEM010...U... HCEM020...U... HCEM050...U... HCEM100...U... HCEM200...U... HCEM500...U... HCEB001...U... HCEB002...U... HCEB005...U... HCE0611AR... HCE0811AR... Operating pressure 0...10 mbar 0...20 mbar 0...50 mbar 0...100 mbar 0...200 mbar 0...500 mbar 0...1 bar 0...10 mbar 0...20 mbar 0...50 mbar 0...100 mbar 0...200 mbar 0...500 mbar 0...1 bar 0...2 bar 0...5 bar 600...1100 mbar(a) 800...1100 mbar(a) Proof pressure3,5 250 mbar 500 mbar 750 mbar 1.2 bar 2 bar 2 bar 3 bar 250 mbar 500 mbar 750 mbar 1.2 bar 2 bar 2 bar 3 bar 6 bar 7 bar 3 bar 3 bar Burst pressure4,5 500 mbar 750 mbar 1.2 bar 2 bar 2 bar 2 bar 5 bar 500 mbar 750 mbar 1.2 bar 2 bar 2 bar 2 bar 5 bar 7 bar 7 bar 5 bar 5 bar Other pressure ranges are available on request. Please contact Sensortechnics. Specification notes: 1. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. 2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. 3. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element. 4. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to the housing. 5. The HCE common mode pressure is 2 bar for all devices up to 500 mbar and 7 bar for all other devices. Common mode pressure is the maximum pressure that can be applied to both ports of a differential pressure sensor simultaneously without damaging the sensor housing. 6. Extended temperature ranges on request. Please contact Sensortechnics. 7. Max. delay time between pressure change at the pressure die and signal change at the output. 8. The response time depends on the adjusted internal A/D resolution of the sensor. For 14 bit it is typ. 1 ms. Other A/D resolutions and reponse times are available on request. Please contact Sensortechnics for further information. 9. Sensors with lower current consumption are available on request. Please contact Sensortechnics for further information. E / 11652 / A 2/11 www.sensortechnics.com HCE Series Miniature amplified pressure sensors PERFORMANCE CHARACTERISTICS (Vs = 5.0 V, TA = 25 C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS, pressure applied to high pressure port) All HCE...5 devices (VS = 5.0) Characteristics Total accuracy (0...85 C)1 Response delay7, 8 A/D resolution8 D/A resolution Current consumption (no load)9 HCE0611..., HCE0811... all other devices 1 14 11 5 Min. Typ. Max. 1.0 0.5 Units %FSS ms bi t mA HCE...R...5 (barometric devices) Characteristics Output at min. specified pressure Full scale span (FSS)2 Full scale output Output at min. specified pressure Full scale span (FSS)2 Full scale output Min. 0560 6B C 6 0.21 4.21 Typ. 0666 6666 6C C C 0.25 4.00 4.25 Max. 076C Unit D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S Count Hex 6D D 2 0.29 V 4.29 A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S HCE...U...5 (unidirectional devices) Characteristics Zero pressure offset Full scale span (FSS)2 Full scale output Zero pressure offset Full scale span (FSS)2 Full scale output Min. 05E 3 6C 49 0.23 4.23 Typ. 0666 6666 6C C C 0.25 4.00 4.25 Max. 06E 9 Unit D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S Count Hex 6D 4F 0.27 V 4.27 A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S HCE...B...5 (bidirectional devices) Characteristics Zero pressure offset Full scale span (FSS)2 Output Min. 3916 Typ. 3999 6666 6C C C 0666 2.25 4.00 4.25 0.25 Max. 3A 1C 6D 4F 06E 9 2.27 4.27 0.27 Unit D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC at max. specified pressure at min. specified pressure 6C 49 05E 3 2.23 Count Hex A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S Zero pressure offset Full scale span (FSS)2 Output at max. specified pressure at min. specified pressure 4.23 0.23 V E / 11652 / A 3/11 www.sensortechnics.com HCE Series Miniature amplified pressure sensors PERFORMANCE CHARACTERISTICS (Vs = 3.0 V, TA = 25 C, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS, pressure applied to high pressure port) All HCE...3 devices (VS = 3.0) Characteristics Total accuracy (0...85 C)1 Response delay7, 8 A/D resolution8 D/A resolution Current consumption (no load)9 HCE0611..., HCE0811... all other devices 1 14 11 3 Min. Typ. Max. 1.0 0.5 Units %FSS ms bi t mA HCE...R...3 (barometric devices) Characteristics Output at min. specified pressure Full scale span (FSS)2 Full scale output Output at min. specified pressure Full scale span (FSS)2 Full scale output Min. 09D 0 5F 25 0.23 2.23 Typ. 0A A A 5555 5F F F 0.25 2.00 2.25 Max. 0B 85 Unit D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S Count Hex 60D 9 0.27 V 2.27 A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S HCE...U...3 (unidirectional devices) Characteristics Zero pressure offset Full scale span (FSS)2 Full scale output Zero pressure offset Full scale span (FSS)2 Full scale output Min. 0A 3D 5F 92 0.24 2.24 Typ. 0A A A 5555 5F F F 0.25 2.00 2.25 Max. 0B 17 Unit D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC S Count Hex 606C 0.26 V 2.26 A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S HCE...B...3 (bidirectional devices) Characteristics Zero pressure offset Full scale span (FSS)2 Output Min. 34E 8 Typ. 3555 5555 5F F F 0A A A 1.25 2.00 2.25 0.25 Max. 35C 2 606C 0B 17 1.26 2.26 0.26 Unit D IG IT A L P E R F O R M A N C E C H A R A C T E R IS T IC at max. specified pressure at min. specified pressure 5F 92 0A 3D 1.24 Count Hex A N A L O G U E P E R F O R M A N C E C H A R A C T E R IS T IC S Zero pressure offset Full scale span (FSS)2 Output at max. specified pressure at min. specified pressure 2.24 0.24 V E / 11652 / A 4/11 www.sensortechnics.com HCE Series Miniature amplified pressure sensors SPI - SERIAL PERIPHERAL INTERFACE Introduction The HCE is capable to generate a digital output signal. The device runs a cyclic program, which will store a corrected sensor value with 14 bit resolution about every 500 s within the output registers of the internal ASIC. This cyclic program runs independent from the bus communication. In order to use the pressure sensor for digital signal readout, it should be connected to a SPI Master device. SPI specifies four signals: The clock (CLK) is generated by the master and input to all slaves. MOSI carries data from master to slave. MISO carries data from slave back to master. A slave select line (SS) allows individual selection of a slave device. In general the HCE series supports all combinations of clock phase (CPHA) and polarity (CPOL). By default it is programmed to CPHA = 0 and CPOL = 0, which means that data transmission starts with the rising first clock edge (see Fig 1). Slave select The falling edge of the SS line indicates the beginning of the transfer. Additionally the SS line must not be negated and reasserted between the three bytes to be transmitted. Data operation The MOSI line should always be set to high level. So there is no data transmission from master to slave. Because of internal configuration the slave will answer the first byte with an FFxh. The second and third byte contain the 15 bit pressure information (see Fig. 2). SPI Modes A pair of parameters called clock polarity (CPOL) and clock phase (CPHA) determine the edges of the clock signal on which the data are driven and sampled. Each of the two parameters has two possible states, which allows for four possible combinations, all of which are incompatible with one another. For further information please refer to Sensortechnics SPI bus application note SCK cycle SCK (CPOL=0) MOSI MISO SS Sampling Fig. 1: 1 2 3 4 5 6 7 8 MSB LSB MSB LSB Example of a standard 1 byte SPI data transfer for CPHA=0 and CPOL=0 Data Byte 1 MOSI MISO 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 X 1 1 Data Byte 2 1 1 1 1 1 1 1 1 Data Byte 3 1 1 1 1 1 1 X P14 P13 P12 P11 P10 P9 P8 P7 P6 P5 P4 P3 P2 P1 P0 Relevant data Fig. 2: 3 byte data stream between HCE sensor and master containing the pressure value as a 15 bit information 5/11 E / 11652 / A www.sensortechnics.com HCE Series Miniature amplified pressure sensors SPI - SERIAL PERIPHERAL INTERFACE (cont.) Interface parameters Parameter Input high level Input low level Output low level Pull-up resistor Load capacitance @ MISO Input capacitance @ each pin Signal clock frequency MISO hold time after SCK sample slope MOSI setup time before SCK sample slope /SS setup time before SCK sample slope CMISO CSPI_IN fSCK tSPI_HD_MISO tSPI_SU_MOSI tSPI_SU_SS 100* 200 2/fCLK 10 ns 500 400 10 640 Symbol Min. 90 0 Typ. Max. 100 10 10 Unit % of V s pF kHz ns * recommended Note: Sensortechnics recommends communication speeds of at least 100 kHz (max. 640 kHz). Please contact your nearest Sensortechnics sales office for further information. t SPI_SU_SS t SCK (CPOL=0) SPI_SU_MOSI t SPI_HD_MISO MOSI MISO SS Fig. 3: Timing characteristics E / 11652 / A 6/11 www.sensortechnics.com HCE Series Miniature amplified pressure sensors PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS HCE...E8... SMD dual port, same side Straight ports Bottom view 12.70 5678 4.50 Pin 1 Connection +Vs GND Vout MISO C LK SS I/C * MOSI 3 16 2 6.50 1.28 3 4 5 6 7 8 4321 4.06 10.70 4.20 3 HIGH PRESSURE PORT 1.90 2 3 LOW PRESSURE PORT 0.46 2.54 third angle projection dimensions in mm HCE...E9... SMD dual port, same side Barbed ports O 2.20 0.1 Bottom view 12.70 4.67 5678 6.70 * Internal connection. Do not connect for any reason Pin Connection +Vs GND Vout MISO C LK SS I/C * MOSI O 2.20 0.1 O 3.0 0.1 00 7. 1 2 3 16 4 5 6 2.50 0.2 5 0.2 HIGH PRESSURE PORT 2.0 4321 10.70 3,12 4.0 7 8 * Internal connection. Do not connect for any reason 5.21 6.87 LOW PRESSURE PORT 2.54 0.46 third angle projection dimensions in mm E / 11652 / A 7/11 www.sensortechnics.com HCE Series Miniature amplified pressure sensors PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS (cont.) HCE...H8... SMD single port Straight port Top view 12.70 8765 Pin 1 2 3 4 Connection +Vs GND Vout MISO C LK SS I/C * MOSI 16 2 9.50 5 6 7 8 4.06 1.28 1234 10.70 2.54 0.46 HIGH PRESSURE PORT 1.90 * Internal connection. Do not connect for any reason 3.70 3 third angle projection 3 4.2 dimensions in mm HCE...H9... SMD single port Barbed port Top view Pin 1 2 3 4 Connection +Vs GND Vout MISO C LK SS I/C * MOSI 12.7 8765 16.0 10.5 5 6 7 8 1234 10.7 3.8 6.2 HIGH PRESSURE PORT 9.0 * Internal connection. Do not connect for any reason 2.8 third angle projection O 2.2 O 3.0 6.0 dimensions in mm E / 11652 / A 8/11 www.sensortechnics.com HCE Series Miniature amplified pressure sensors PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS (cont.) HCE...Q8... SMD dual port, opposite side Straight ports Bottom view 12.70 5678 Pin 1 2 3 Connection +Vs GND Vout MISO C LK SS I/C * MOSI 2 9.50 16 1.28 4 5 6 7 8 4321 10.70 4.20 3 HIGH PRESSURE PORT 3 6.70 LOW PRESSURE PORT 4.06 * Internal connection. Do not connect for any reason 1.90 0.46 2.54 third angle projection dimensions in mm HCE...Q9... SMD dual port, opposite side Barbed ports Top view 12.7 8765 6.2 4.0 Pin 1 2 3 4 5 6 Connection +Vs GND Vout MISO C LK SS I/C * MOSI 16 10.5 1234 10.7 3.1 6.9 7 8 LOW PRESSURE PORT 5.0 HIGH PRESSURE PORT * Internal connection. Do not connect for any reason 2.2 6.0 O 2.2 O 3.0 third angle projection dimensions in mm 9/11 E / 11652 / A www.sensortechnics.com HCE Series Miniature amplified pressure sensors HOUSING OPTIONS Different housing options are available on request. Please contact Sensortechnics. Dual Inline Packages (DIP) (Sample package shown: DIP dual port, same side) 12.70 4.50 5678 3.0 16.25 9.0 5.60 6.70 16.0 6.50 4321 10.70 HIGH PRESSURE PORT 4.20 3.0 3.0 LOW PRESSURE PORT 2.54 0.46 1.90 2.0 third angle projection dimensions in mm Single Inline Packages (SIL) (Sample package shown: SIL same top side) 12.70 7.85 4.85 2 1.90 3 10.30 4321 0.51 2.54 10.70 1.90 HIGH PRESSURE PORT third angle projection dimensions in mm 6.70 3 10.70 16 0.25 1.45 LOW PRESSURE PORT E / 11652 / A 10/11 www.sensortechnics.com 4.20 HCE Series Miniature amplified pressure sensors ORDERING INFORMATION Series Options HCE Pressure range 0611 0811 M010 M020 M050 M100 M200 M500 B 001 (B001A) Pressure mode B U Calibration Bidirectional Unidirectional E* Housing SMD, 2 ports, same side Porting 8* Straight 9** Barbed Grade P Prime Voltage 3 5 3V 5V 600...1100 mbar A* Absolute 800...1100 mbar D 10 mbar G 20 mbar 50 mbar 100 mbar 200 mbar 500 mbar 1 bar 1 bara Differential Gage R* Barometric H** SMD, 1 port Q* SMD, 2 ports, opposite side B 002 B 005 2 bar 5 bar * only available for pressure ranges 0611, 0811, B 001, B 002 * for pressure ranges 0611, 0811 Housings Q only available * standard for up to 1 bar. Please devices up to 500 mbar and contact Sensortechnics. barometric ranges * standard for differential ** standard for devices, "D" devices from ** standard for absolute 1 bar and gage devices, "A" and "G" Example: HCE M050 D B E 8 P 5 Note: Devices highlighted in grey are preferred stock items Custom specific pressure ranges and mechanical or electronic sensor modifications are widely available: * I2C, switching and custom specific outputs * Dual inline packages (DIP) * Single inline packages (SIL) ... etc. Please contact your nearest Sensortechnics sales office for further information. Sensortechnics PRO services: * Extended guarantee period of 2 years * Custom product modifications and adaptations even for small quantities * Advanced logistics models for supply inventory and short delivery times * Technical support through application engineers on the phone or at your site * Traceability of each sensor through serial numbers on request * No product specification changes without customer notification * No product obsolescence without very early prior notice * Fastest possible technical response for design and QA engineers * Long term product availability for your spares and service needs ... plus other services on request Sensortechnics reserve the right to make changes to any products herein. Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. E / 11652 / A 11/11 www.sensortechnics.com |
Price & Availability of HCE0811ABE8P3 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |